The ventilation system uses the cooling tower special aluminum axial flow fan, with anteverted design wind blade, streamlined inlet blowdryer;
advantages: low wind resistance, large blast capacity, low noise, good performance, high efficiency. Use closed low noise cooling tower motor;
advantages:small volume,lightweight,excellent performance,durable.
Made of PVC,the saturated wet hot air meets the drift eliminator, congeal to water drops and slip to the water collector,it can effectively reduce the fluttering of water,saving water.
AOSUA cooling coiled pipe's design ensures high cooling efficiency. the design of the double pipe make the pipe with a compact arrangement, reduces the flow resistance of the air at the same time. This design also increases the water-loading, and effectively uses the coiled pipe. According to the material, it can be divided into two types:SUS304 condensing coiled pipe and red copper condenser coiled pipe.
AOSUA's air-inlet grille is made by adopting corrosion resistance PVC, its function is to prevent dust and dirt to enter the unit, avoid direct sunlight and splash water, reduce a part of the algae forming, and easy to clean the sink.
Use a closed cooling tower pump with a big flow, low lift, high efficiency, low noise, low power. The water tank is made of 304 stainless steel.
A closed cooling tower that keeps the system clean and free of contamination in a closed loop. This creates two separate fluid loops: (1) an external loop, in which the water spray circulates over the coil and mixes with the outside air, and (2) an internal loop, in which the process fluid to be cooled circulates within the coil. During operation, heat is transferred from the hot fluid in the coil to the spray water and then to the atmosphere as some of the water evaporates. In addition to chiller applications and industrial process cooling, closed cooling towers are often used with heat pump systems that require closed loop cooling.
Closed cooling towers operate in a similar manner to open cooling towers, except that the heat load to be discharged is transferred from the process fluid (the fluid being cooled) to the ambient air via a heat exchange coil. The coils are used to isolate the process fluid from the outside air, keeping it clean and contamination free in a closed loop. This creates two separate fluid loops: (1) an external loop where the water injection circulates over the coil and mixes with the outside air, and (2) an internal loop where the process fluid circulates within the coil. During operation, heat is transferred from the internal loop to the coil and then to the atmosphere as some of the water evaporates.